Reading the master infrastructure.yml (schema 5) ​

How Invoke-ZtpEnvironment.ps1 reads the master infrastructure.yml, the one environment file every Azure Local tool reads, and where each of its keys goes.

The master file and its schema live in azurelocal-toolkit: infrastructure.schema.json, the examples (examples/lom-management-ztp.yml is a simplified-provisioning example with every port listed) and README.md, which describes every key. ZTP reads schema 5.x. Schema 5.2 adds the keys ZTP needs for each machine's ports, BIOS and run folders; schema 5.3 adds bios_during_provisioning, networking.management.static_method and provisioning_dhcp_range, nodes[].maintenance_address, provisioning.simplified.maintenance_password and _metadata.scope; schema 5.4 puts every other ZTP setting in the master file (see Every setting is a key).

The two templates ​

The toolkit has two templates. Start from the one that matches what you do after ZTP:

  • ZTP only, with no automation after it: the ZTP-only template (schema 5.3, _metadata.scope: ztp). It holds only what ZTP reads, and the toolkit's validator requires only those keys. The toolkit is adding it; it isn't published yet.
  • ZTP, then OS configuration and deployment: the full template. ZTP reads its part and ignores the rest.

ZTP accepts _metadata.scope and ignores every key it doesn't read. To grow a ZTP-only file into the full one, add the sections and set _metadata.scope: full (or remove it).

Pass the file the same way as before:

powershell
./scripts/simplified-provisioning/Invoke-ZtpEnvironment.ps1 -InfrastructureFile D:\envs\site-01\infrastructure.yml

The older environment-file layout still works and is deprecated. Prerequisites lists every value ZTP reads, with an example and where to get it.

How the file is read ​

  1. The format. A file with _metadata.schema_version (or schema_version at the top) is schema 5. Anything else is the older layout, read as before.
  2. The check. When an azurelocal-toolkit clone sits next to this repository (..\azurelocal-toolkit), or $env:AZL_TOOLKIT_ROOT names one, ZTP runs its Test-AzlInfrastructure: the schema and the toolkit's rules. Its errors stop the run, with their rule IDs; its warnings are shown. Without the toolkit, only ZTP's own checks run. Either way, ZTP then checks what it needs itself (Test-ZtpInfrastructureV5): _metadata.schema_version is 5.x, scenario.os_install: simplified, exactly one management port per node, every vault a keyvault:// reference names is in key_vaults, every secret is in the provisioning admin vault's subscription, and one BMC login (hardware.bmc) for every node.
  3. The mapping. The file is mapped onto the keys the scripts read (ConvertFrom-ZtpInfrastructureV5, the table below), and ZTP's key check runs on the result. Every problem is named in schema 5 paths (ConvertTo-ZtpSchema5Message), for example site.time_zone is required or nodes[0] (node-01) management port mac_address is required, and all of them at once.

Where each key goes ​

ZTP readsFrom schema 5
Node name, edge machine namenodes[].name
Management address, MAC and port nameThe node's management port: the nodes[].network_adapters entry with role management and an ip_assignment other than none (its ip_address, mac_address, name). Without network_adapters: nodes[].management.ip_address, mac_address, adapter_name.
Management mode, per nodeThat port's ip_assignment, kept as it is: dhcp_reservation (Mode A, Reserved: the port keeps DHCP, ip_address optional), static (Mode B or C), dhcp (no reservation, warned), preconfigured. Static is Mode B (Static with DHCP) when networking.management.provisioning_network is dhcp and the management port also has role provisioning; otherwise Mode C (Static without management DHCP). See Management address modes. Without network_adapters: networking.management.ip_assignment (default static).
The node's ports, for the handoffEvery nodes[].network_adapters entry (name, mac_address, roles, ip_assignment, ip_address) goes to the node list, so the handoff can match each port Azure reports by MAC. ZTP doesn't configure them.
Management VLANnetworking.management.vlan_id, the VLAN the host tags (0 for an access port). Without it, the management port's vlan_id (0 when its vlan_mode is access).
Serial number, BMC addressnodes[].serial_number, nodes[].bmc.ip_address
Arc machine namenodes[].arc_machine_name, else nodes[].arc_resource_name, default the node name. The service currently overwrites it at claim time (open research item); the handoff records the name Azure used.
Maintenance address (the Device stage)nodes[].maintenance_address, else the ip_address of the node's port with role provisioning (and not management), for example a dhcp_reservation port. Without either, the Device stage scans networking.management.provisioning_dhcp_range (default: the management subnet) on TCP 20001 and finds the node by its management MAC.
BIOS settings (final)hardware.bios, with nodes[].bios merged over it. Boot applies them; Restore sets any temporary key back to them.
BIOS settings for the install onlyhardware.bios_during_provisioning, with nodes[].bios_during_provisioning merged over it. Boot applies them over the final ones (they win); Restore sets each back to the final value, or to the value Boot saved before changing it.
Who sets a static management addressnetworking.management.static_method: device (default; the Device stage, by MAC, with the site Automatic) or site (the OS install, from the site's Manual setting)
Where the Device stage scansnetworking.management.provisioning_dhcp_range (start, end; at most 4096 addresses)
Subnet, gateway, DNS serversnetworking.management.subnet, gateway, dns_servers
Site range (only with static_method: site)networking.management.site_ip_range
How the maintenance environment reaches Azurenetworking.management.provisioning_network (the ports with role provisioning carry it)
Tenant, regionazure.tenant_id, azure.location
Site display name, time zonesite.name, site.time_zone
Subscription and resource group of the site and edge machinesprovisioning.simplified.subscription_id and resource_group, else azure.subscription_id and resource_group
Site resource name, maintenance ISO, OS versionprovisioning.simplified.site_name, maintenance_iso, provisioning.os_version
SMB shareprovisioning.simplified.media_share.name, host or host_adapter
Run foldersprovisioning.simplified.media_path, evidence_path
Provisioning administratorprovisioning.simplified.admin.username; the vault and secret from admin.password (keyvault://<vault>/<secret>), and that vault's subscription_id and resource_group from key_vaults[]
The maintenance environment's edgeuser passwordprovisioning.simplified.maintenance_password (keyvault://<vault>/<secret>, in key_vaults, in the provisioning admin vault's subscription). Schema 5.3. Without it: Password1.
BMC loginhardware.bmc.username (a keyvault:// reference or the name itself) and hardware.bmc.password (a keyvault:// reference). Required.
Vendorhardware.vendor (picks config/oem/<vendor>.json, the BMC layer)
Resource provider object IDazure.hci_resource_provider_object_id
Tagstags
BIOS actions derived from the inventory (5.4)nodes[].san.hbas[].slot and type, nodes[].network_adapters[].slot, provisioning.simplified.isolate_san_adapters, enable_embedded_nics. See Hardware-aware BIOS actions.
Azure site choices (5.4)provisioning.simplified.create_resource_group, configuration_name, managed_resource_group_name, apply_site_settings, use_key_vault_configuration, assign_provisioning_roles, assign_hci_rp_role, network_kind, ntp, site_mode, deployment_name
Stage budgets, retries, USB image, Configurator service (5.4)provisioning.simplified.timeouts.*, retry_provision_os, skip_azure_check, include_preview, max_train, usb_image, maintenance_environment, media_share.account_name, media_share.keep
BMC behaviour (5.4)hardware.bmc.rfs_write_attribute (default: true for Dell, false for the other vendors), hardware.bmc.verify_certificate (default false)

Limits of the mapping, which the check names: ZTP reads every secret in the provisioning administrator vault's subscription, and uses one BMC login for every node (hardware.bmc; a node's own bmc login must be the same).

Not read by ZTP ​

These keys belong to OS configuration and deployment. ZTP doesn't map them, doesn't require them, and a file can keep them:

KeyWho reads it
hardware.sbeOS configuration and deployment. ZTP accepts it and prints Note: hardware.sbe ignored: SBE belongs to OS configuration. The OS install discovers its own SBE (the ProvisionOs job's SBEDiscoveryDownload step).
identity.local_adminThe deployment admin, created in OS configuration.
networking.ntp_serversTime on the host, set in OS configuration. The site's time setting is Automatic.
The other ports in nodes[].network_adapters (no role management or provisioning)OS configuration (DHCP off, unused adapters disabled). The provisioned OS names its ports Port0 to Port6, so find them by MAC there.
hardware.model, site.code, nodes[].rack_positionNot used by any stage.

What ZTP does with the ports ​

The Device stage. Before the claim, Set-ZtpDeviceConfiguration.ps1 sets a static management address on the port named by its MAC in the maintenance environment, through the Configurator App's REST service on the maintenance address (TCP 20001). Without a maintenance address it finds the node by scanning provisioning_dhcp_range for the service and matching the MAC. See The Device stage and Appendix B.

The claim. With static_method: device (the default), the edge machine's request carries no networkAdapters entry: the site is Automatic, and the address the Device stage set is the only static the node gets. With static_method: site, a static management port gets one entry, keyed by the port's MAC: ipAssignmentType: Manual, the address, mask, gateway, DNS servers and VLAN. The OS install accepts that MAC but doesn't use it: the address goes to the first ready port, which can be a storage port (see Static IP lands on the wrong NIC). For dhcp, dhcp_reservation and preconfigured there's no entry either way.

The Network stage. After Ready, Set-ZtpManagementAddress.ps1 verifies each management address on the port named by its MAC, through Azure's per-NIC report (edgeMachines/<node>/networkAdapters, api-version 2026-10-01). It matches the management port's mac_address against each adapter's reported MAC, whatever the separators and case, and stops when none matches. It changes nothing: a static address the OS install reset to DHCP is recorded as left to OS configuration, which sets it by MAC. -ApplyThroughAzure (opt-in, unreliable: the job never started on two live runs) moves it through jobs/ApplyConfiguration instead. See The Network stage.

The site's network setting. Automatic with static_method: device (the default). With static_method: site, Manual when any management address is static, over site_ip_range (default: the lowest to the highest static address); Automatic otherwise. See The site's network setting.

The maintenance environment. It reaches Azure through a port with role provisioning, before the machine is claimed, and takes DHCP there (provisioning_network: dhcp). On a machine whose management network has no DHCP, mark data ports that do get DHCP as provisioning, as lom-management-ztp.yml does. A static address in the maintenance environment (provisioning_network: static) is a warning: Learn documents only the Configurator app for it, and whether the USB image can carry a preset address is an open research item.

The other ports. ZTP doesn't touch them. Turning DHCP off on them and disabling unused adapters is OS configuration (Phase 03 OS Configuration).

Hardware-aware BIOS actions (schema 5.4) ​

hardware.bios and hardware.bios_during_provisioning are raw vendor attribute names (Slot2: Disabled); only someone who knows Dell's names can fill them in. From schema 5.4 ZTP derives the two actions that need them from the inventory, and the raw maps stay as explicit overrides.

The file saysZTP doesSwitch (default)
nodes[].san.hbas[].slot: "Slot 2"Turns that PCIe slot off in the BIOS for the install (so the maintenance environment can't install onto a SAN LUN). The Restore stage puts it back to the value Boot found; if Boot found it already disabled (a crashed earlier run left it), to the vendor's enabled value.provisioning.simplified.isolate_san_adapters (true when THIS node lists san.hbas, else false)
A management or provisioning port with slot: EmbeddedMakes sure the embedded NICs are enabled, and leaves them so (Dell ships them as DisabledOs).provisioning.simplified.enable_embedded_nics (true)

The slot label to attribute mapping is data, in config/oem/<vendor>.json, section bios: slot_attribute (Slot{n}), disabled, enabled, embedded_nic_attribute, embedded_enabled. Only Dell has one (verified_models: AX-760; on another model the plan prints a warning to confirm the attribute, and does not block). For a vendor without it an HBA must name its own attribute, nodes[].san.hbas[].bios_attribute (with optional bios_disabled_value and bios_enabled_value); otherwise ZTP stops. An unrelated raw key in bios_during_provisioning does not excuse the missing mapping, and ZTP never guesses a name. To add a vendor, add its bios section.

Restore target: ZTP does not assume the original value was the vendor's "enabled". Boot saves each attribute's value before it changes anything, and Restore puts that back (BootDriverDisabled stays BootDriverDisabled). The one exception is a slot Boot found already at the isolating value: it goes back to the enabled value. If the saved value is lost, Restore stops and asks for hardware.bios.<attribute>. An explicit hardware.bios value wins. The handoff records biosRestoreComplete and biosNotRestored per node, so an unfinished restore is visible.

Precedence: an explicit key (in hardware.bios, nodes[].bios or the bios_during_provisioning twins) always wins over a derived one for the same attribute and phase; two derivations that target one attribute with different values are a problem. The plan output prints each decision with its reason:

PLAN: node-01 BIOS Slot2 Disabled for the install because nodes[0].san.hbas[0] is in Slot 2 (the Restore stage sets it back to Enabled)
PLAN: node-01 BIOS EmbNic1Nic2 Enabled because the management port 'Embedded NIC 1' of nodes[0] is in slot Embedded (the OS can't see disabled embedded NICs)

Everything that can be wrong is found before ZTP touches a machine: a slot label that is not Slot <n>, a slot that also holds a network port (the port's label is read loosely, so Slot 2 Port 1 or PCIe Slot 2 count), a vendor with no mapping and no bios_attribute, two derivations on one attribute. The Boot stage then reads every node's BIOS and the BMC's attribute registry first and stops before it changes any node, if an attribute is missing (saying why ZTP looked for it) or the registry does not allow the value (attribute, node, value, the allowed ones). If the registry cannot be read it warns and continues; whether the attribute exists is always checked. Switches are read strictly: a boolean, or the strings true and false in any case; 0 or yes is a problem naming the key.

Every setting is a key (schema 5.4) ​

The master file holds every setting ZTP reads; ZTP keeps no key of its own. Each new key has the value ZTP used before it existed as its default, so a file without them behaves as it always did. variables-audit.md lists every action, threshold and literal in the stages with the key that controls it, and the few that stay fixed with the reason.

Open items ​

  • The Arc machine name. ZTP sends arcMachineResourceId named after arc_machine_name, but in live runs (2026-11) the service overwrote it at claim time: the Arc machines came out as ROE1-<id> and then <device-id>-1. The handoff reads the name actually used from the edge machine after Ready.
  • A static address in the maintenance environment. Unresearched beyond the Configurator app; see above.