Skip to main content

Fibre Channel Fabric Maintenance

Reference Azure

DOCUMENT CATEGORY: Reference SCOPE: Fibre Channel fabric maintenance PURPOSE: Reference for FC switch firmware update, port replacement, fabric merge/split MASTER REFERENCE: Microsoft Learn — Connect an external storage array to Azure Local

Status: Active

This document provides maintenance procedures for Fibre Channel fabrics used in Azure Local SAN-attached deployments, covering firmware updates, port and SFP replacement, and a recurring maintenance schedule. Procedures cover both Brocade Fabric OS and Cisco MDS NX-OS platforms.

FC Switch Firmware Update​

Firmware updates require a maintenance window — typically one fabric at a time so the cluster remains operational on the surviving fabric. MPIO on each node automatically routes I/O through the active fabric while the other is updated.

Pre-Update Checklist​

  1. Confirm current MPIO path count on each node:
    mpclaim -s -d
  2. Confirm the cluster is Healthy:
    Get-Cluster
    Get-ClusterNode
  3. Schedule maintenance window (~2 hours per fabric).
  4. Notify relevant stakeholders and create a change record.

Brocade Firmware Update​

# SSH to the switch
ssh admin@brocade-fab-a.corp.azurelocal.cloud

# Check current version
firmwareshow

# Stage firmware (FTP from staging server)
firmwaredownload

# Switch reboots automatically — wait ~10 minutes
# After reboot, verify
firmwareshow

During the update, Fabric B continues serving I/O. After Fabric A returns, MPIO automatically reclaims paths within ~30 seconds.

Cisco MDS Firmware Update​

install all kickstart bootflash:m9700-sf3ek9-kickstart-mz.X.Y.Z.bin \
system bootflash:m9700-sf3ek9-mz.X.Y.Z.bin

For a non-disruptive upgrade (NDU), confirm both supervisors are present and active before initiating the install.

Post-Update Validation​

mpclaim -s -d
Get-PhysicalDisk | Where-Object BusType -eq 'Fibre Channel' |
Select-Object FriendlyName, OperationalStatus

Path count must match the pre-update value. If paths do not recover within 60 seconds, check ISL connectivity and zone enforcement on the updated switch before escalating.

From Azure Local 2610 the SANDiagnostics log role collects MPIO, Fibre Channel and iSCSI initiator, disk, volume, CSV and event log data in one pass (see Roles available for filtering logs). Attach that collection when you escalate a path-recovery problem to the array or switch vendor.


Port (Cable/SFP) Replacement​

When a fabric port shows persistent CRC errors or link flaps, use the following procedure to isolate and replace the affected component with minimal I/O disruption.

  1. Identify the affected port:
    • Brocade: porterrshow
    • Cisco MDS: show interface counters
  2. Cross-reference WWPN aliases to identify the affected node and HBA port.
  3. Create a change record.
  4. Disable the affected port to force MPIO failover:
    • Brocade: portdisable <port>
    • Cisco MDS: enter interface fc1/N then shutdown
  5. Wait 60 seconds and confirm MPIO has failed all paths for that port over to the redundant fabric.
  6. Replace the cable and/or SFP.
  7. Re-enable the port; wait 30 seconds; confirm path count recovers to the expected value.
  8. Reset error counters to establish a clean baseline:
    • Brocade: portstatsclear <port>
    • Cisco MDS: clear counters interface fc1/N
Cleaning fiber connectors

Use an inspection microscope and end-face cleaner before inserting replacement SFPs. Dirty connectors are a leading cause of CRC errors on single-mode links.


Recurring Maintenance Schedule​

TaskFrequencyOwner
Review fabric error countersWeeklyOperations
Confirm zoneset matches designMonthlyStorage admin
Firmware updatePer vendor advisory or annuallyStorage admin
Cable inspection / fiber cleaningAnnuallyOn-site technician

References​


Cross-references​

  • Phase 03 Task 13 — Configure MPIO & MSDSM — MPIO verification commands referenced in the firmware update and port replacement sections above.
  • Appendix P — FC Fabric Configuration — fabric zoning and port layout that this appendix maintains.

Procedures verified against Brocade Fabric OS 9.x and Cisco MDS NX-OS 9.x as of 2026-05-02.

For questions about these procedures, refer to the vendor documentation linked above or contact the Azure Local Cloud documentation team.