Task 14: Verify SAN LUN Presentation (Conditional)

The automated run does this task for you

The automated OS configuration run covers this task in the SanVerify step (every WWPN seen; the infrastructure and performance history LUNs visible, RAW, big enough, with two or more paths; every node sees the same disks). Use the manual steps below when you can't use the run, or to understand or troubleshoot what it does. See how the run works.

Runbook Phase 03 Platform

DOCUMENT CATEGORY: Runbook SCOPE: SAN LUN pre-deployment verification PURPOSE: Confirm all required LUNs are visible and infrastructure LUNs remain RAW MASTER REFERENCE: Microsoft Learn — Install the Azure Local operating system for disaggregated deployments (Connect to SAN)

Status: Active

Which storage designs run this task
Storage designThis task
Disaggregated (SAN only)Run it now, on every node, before Arc registration.
Hybrid (Storage Spaces Direct + SAN)Not at initial deployment. SAN LUNs are attached after the deployment (2604 or later; FC WWNs are not zoned until then), and the post-deployment verification in Learn's Connect an external storage array to Azure Local (steps 7 to 10) applies instead.
Storage Spaces Direct onlySkip to Task 15: Complete Combined Script.
Do NOT initialize the infrastructure or performance history LUNs

The infrastructure volume LUN and performance history LUN must remain RAW (no partition table, no file system) until the Azure Local deployment wizard runs. Learn: "Don't initialize the drives, as the deployment expects the drive type to be RAW." If you initialize these LUNs before deployment, the deployment can fail.

Workload LUNs are configured after cluster deployment — see Phase 06 Task 05.


Overview​

This task confirms that all required SAN LUNs are correctly presented to all cluster nodes via MPIO, and that the infrastructure LUNs are in the correct RAW state. This is a verification-only step — no disk initialization occurs.


When to Run​

ScenarioRun?
SAN disaggregated deployment, Fibre Channel or iSCSI✅ Yes — all nodes
Hybrid (S2D + SAN)❌ Not at initial deployment — verify after deployment per Learn
Storage Spaces Direct (S2D) only❌ Skip
After FC zoning or LUN masking changes✅ Yes — re-verify

Prerequisites​

RequirementDetails
Tasks 12 and 13 completeHBA drivers (FC) and MPIO (verified, vendor registered and claimed) configured. iSCSI on 2610: connected by the deployment wizard, see the iSCSI note below
FC zoning complete (disaggregated only)The FC fabric administrator has zoned the node HBAs to the array target ports (Learn's rack aware SAN article says "redundant single-initiator zoning according to the fabric and array vendor design"; Learn does not describe single-target zoning, so follow your fabric and array vendor design) so the LUNs are visible before Arc registration. For a hybrid design, do not zone until after the deployment.
SAN LUNs provisionedOnly the two system LUNs are required before deployment: infrastructure (250 GB or larger) and performance history (20 GB or larger), created on the array and unmasked to all nodes with consistent LUN IDs
FC fabric connectivityHBA ports visible in the fabric; zones active
Coordinate with your SAN administrator

LUN presentation timing must be coordinated with the SAN array administrator. The infrastructure and performance history LUNs are provisioned before this step but left uninitialized. Learn: "Workload LUNs are configured after deployment" (portal deployment, advanced settings); presenting them early is optional and only raises the risk that someone initializes them by accident.

iSCSI on Azure Local 2610

On 2610 the deployment wizard's iSCSI Configuration connects the targets, so do not enable iSCSI on the machines first (see Task 12); there is nothing to verify here yet. On 2604 to 2609, after you connect the targets manually, run the same checks below with BusType iSCSI.


Required LUN Layout​

LUNPurposeMin SizeExpected State
Infrastructure VolumeAzure Local system data250 GBRAW — no partition
Performance HistoryCluster metrics store20 GBRAW — no partition
Workload CSVsVM storagePer capacity planConfigured after deployment (Learn); optional to present earlier, but never initialize them here

Step 1: Rescan and Verify Disks​

Run on each node individually via console, KVM, or RDP.

Toolkit script: scripts/deploy/04-cluster-deployment/phase-03-os-configuration/task-14-verify-san-lun-presentation-conditional/powershell/Verify-SANLUNs-Direct.ps1

# Task 14 - Verify SAN LUN Presentation (run on each node)

# Rescan storage subsystem
Update-HostStorageCache

# List all SAN disks (should include the infrastructure and perf-history LUNs)
Get-PhysicalDisk | Where-Object BusType -in 'Fibre Channel','iSCSI' |
Select-Object FriendlyName, SerialNumber, Size, CanPool, BusType, OperationalStatus |
Format-Table -AutoSize

# Verify infrastructure LUNs are RAW (no partition table)
Get-Disk | Where-Object {
$_.BusType -in 'Fibre Channel','iSCSI' -and $_.PartitionStyle -eq 'RAW'
} | Select-Object Number, FriendlyName, Size, PartitionStyle |
Format-Table -AutoSize

# Confirm MPIO path count per disk
mpclaim -s -d

Expected Results​

CheckExpected
SAN disks visible on all nodes✅ Same LUNs appear on every node (compare UniqueId, disk numbers may differ between nodes)
Infrastructure LUN (≥250 GB)PartitionStyle = RAW
Performance history LUN (≥20 GB)PartitionStyle = RAW
MPIO path count≥2 paths per LUN (2 HBAs × 1 fabric or 2 × 2 with dual-fabric)
OperationalStatusOK for all LUNs
If LUNs are NOT visible on all nodes

Verify the array host entries and LUN masking (WWPNs for FC, IQNs for iSCSI), and for FC the zoning between each initiator WWPN and the array target ports. Re-run zoning configuration and rescan: Update-HostStorageCache. Confirm mpclaim -s -d shows paths.

If a LUN shows multiple entries per node

MPIO is registered but not claiming the disk (lab-verified symptom on a Pure FlashArray: 8 separate disks for 2 LUNs). Verify the New-MSDSMSupportedHW hardware IDs match the array vendor, run the mpclaim -n -i -d claim from Task 13, restart the node and rescan.


Validation Checklist​

  • Infrastructure LUN (≥250 GB) visible on all nodes with PartitionStyle = RAW
  • Performance history LUN (≥20 GB) visible on all nodes with PartitionStyle = RAW
  • No LUN appears more than once per node (MPIO claiming correctly)
  • MPIO path count matches expected value (≥2 per LUN)
  • OperationalStatus = OK for all SAN disks
  • No SAN disk was initialized, formatted or added to the cluster

Alternatives​

The procedures in this task use the scripted methods shown in the tabs above. Additional deployment methods including Azure CLI and Bash scripts are available in the azurelocal-toolkit repository under scripts/deploy/.

MethodDescription
Azure CLIPowerShell-based Azure CLI scripts for Azure resource operations
BashLinux/macOS compatible shell scripts for pipeline environments

← Task 13: MPIO & MSDSM · ↑ Phase 03 · Task 15: Combined Script →


Version Control​

VersionDateAuthorChanges
1.0.02026-05-02Azure Local CloudInitial release
1.1.02026-11-08Azure Local CloudAligned to Azure Local 2610: FC zoning is a disaggregated prerequisite before Arc registration (hybrid zones only after deployment); single-initiator wording follows Learn; only the infrastructure and performance history LUNs are required before deployment; checks cover Fibre Channel and iSCSI bus types; iSCSI 2610 wizard note; fixed Learn links